Construction Method Statements

Construction method statements are basic documents that a site engineer needs when he starts the construction works.
Our website provides hundreds of construction method statements related to civil, electrical, mechanical, plumbing, HVAC and firefighting disciplines.
We recommend you to visit our construction method statement online portal where you can search different documents as per your needs.

Closed Control Units Installation Testing Commissioning Method Statement

Below is the best method statement that covers closed control units installation testing and commissioning on a project site. The mechanical site engineer / site supervisor will give necessary instructions to tradesmen (pipe fitters & duct installers) and provide necessary approved construction/shop drawings of latest revision along with coordinated layouts for ccu installation works. Following […]

Closed Control Units Installation Testing Commissioning Method Statement Read More »

HVAC Method Statements, Method Statements
Method Statement for Installation of Noise Control and Vibration Isolation Equipment

Method Statement for Installation of Noise Control and Vibration Isolation Equipment

This method statement covers on site installation of noise control and vibration isolator equipment associated with all rotating, centrifugal and reciprocating equipment i.e. pumps, chillers, air handling units and pipe connections etc. Procedure defines the steps that will be used to ensure the correct installation of noise control equipment to avoid excess noise and vibration

Method Statement for Installation of Noise Control and Vibration Isolation Equipment Read More »

Construction Method Statements, Method Statements
Download Method Statement For Air & Water Balancing

Water Balancing in Chilled Water System Method Statement

The aim of chilled water balancing in chilled water system is to apply a disciplined procedure of adjustments to water flow rates throughout the chilled water system to meet the particular requirements of the design. Chilled water balancing in hvac system for the flow rates should be carried out to specified tolerances (which may vary

Water Balancing in Chilled Water System Method Statement Read More »

Construction Method Statements, HVAC Method Statements, Method Statements, Testing & Commissioning
Air Balancing Procedure for HVAC System FCU AHU Exhaust Fans & Pressurization Unit

Air Balancing Procedure for HVAC System FCU AHU Exhaust Fans & Pressurization Unit

Below is a precise air balancing procedure that covers the HVAC system equipment and ducting system. Air Balancing For Fan Coil Units Check that all automatic controls are fully commissioned and operating properly All pre-commissioning checks have been carried out Select the specified speed of the Fan Coil Set all the dampers in the grill

Air Balancing Procedure for HVAC System FCU AHU Exhaust Fans & Pressurization Unit Read More »

HVAC Method Statements, Method Statements, Testing & Commissioning
Lifting Shifting and Positioning of Heavy Equipment

Lifting Shifting and Positioning of Heavy Equipment

Project Manager is the overall responsible person for the process implementation of the works. Construction Manager/Site Engineer will be responsible for all construction activities at the site and will directly supervise through erection supervisor/ skilled workmen the work at site. Site Engineer will be responsible for arranging and controlling the inspection and testing activities. Furthermore,

Lifting Shifting and Positioning of Heavy Equipment Read More »

Construction Method Statements, Method Statements
Flushing Procedure For Chilled Water System

Flushing Procedure For Chilled Water System & Chemical Treatment

Chilled water or cooling water system is mostly a closed system that requires strict monitoring and control of certain parameters. Water during circulation evaporates and it increases the suspended particle concentration, which in result creates scale formation and corrosion etc. Therefore the chemical treatment of any water system is very much necessary on regular basis.

Flushing Procedure For Chilled Water System & Chemical Treatment Read More »

HVAC Method Statements, Method Statements, Testing & Commissioning
Chilled Water Pressurization Unit Testing and Commissioning Method Statement

Chilled Water Pressurization Unit Testing and Commissioning Method Statement

The purpose of this procedure is to define the step by step method to implement the correct practices for the pre commissioning & commissioning of chilled water pressurization unit. By following this method statement contractor shall ensure that pressurization unit installation and testing works comply with the project requirements/specifications and serves the intended function to

Chilled Water Pressurization Unit Testing and Commissioning Method Statement Read More »

HVAC Method Statements, Method Statements, Testing & Commissioning
Installation of Air Handling Units AHU & FAHU

Method Statement for Installation Of Air Handling Unit AHU & FAHU

Below is the brief method of statement for the installation of air handling unit which is applicable for both AHU & FAHU installation. On this page we have given in detail only one section of overall method statement that covers mainly installation and inspection part. Complete method statement shall include other sections as well as

Method Statement for Installation Of Air Handling Unit AHU & FAHU Read More »

HVAC Method Statements, Method Statements
error: Content is protected !!