Web Master

BMS System Control devices

Electrical & Mechanical BMS Control Devices

Chilled Water Automatic control valves 2″ and smaller shall be screwed type, of red brass material and valves 2½” and larger shall be cast iron type and flanged. Valves shall be ANSI- rated to withstand the pressures and temperatures encountered. Valves shall have stainless-steel stems and spring loaded Teflon packaging with replaceable discs. All valves […]

Electrical & Mechanical BMS Control Devices Read More »

Building Management System

BMS Energy Management Software Control Functions

Generally any energy management control software shall provide as a minimum the following functions. Each function is detailed separately. Time Control Modes There shall be no limit to the number of time schedules each of which can have any point or number of points assigned. Each time programme shall operate over a seven-day week and allow

BMS Energy Management Software Control Functions Read More »

Building Management System

BMS Alarms Reporting and Functions

The BMS provides a vehicle for the visibility of plant failure, patterns, annunciation of alarms and the reporting function. In particular it shall provide the standard functions stated below: Alarms shall be generated under the following conditions: Digital input contact change from normal to alarm condition (either open or closed). Digital input condition either matches

BMS Alarms Reporting and Functions Read More »

Building Management System
Air Handling Unit AHU FAHU Testing and commissioning Method Statement

Sequence of Operation for Variable Volume Type FAHU with Plate Heat Recovery

Below sequence of operation is for Variable Volume Type FAHU with Plate Heat Recovery system. The system shall be variable volume package Fresh Air Handling Unit. The scope of the unit shall consist of: Supply Side accessories Intake motorized damper Panel (Pleated) Filter Bag Filter Cooling Coil Supply Fan (with VFD) Plate Heat Exchanger Intake and discharge

Sequence of Operation for Variable Volume Type FAHU with Plate Heat Recovery Read More »

Building Management System, HVAC Method Statements, Testing & Commissioning
BMS Controller

Technical Requirements for BMS Programmable Controllers

The programmable controllers shall be 16bit type or more of the fully intelligent type, capable of performing all Control and Energy Management functions assigned to them, independent of any other BMS equipment. Programmable controllers may be of modular or fixed hardware construction or a combination of both. The basic set of configuration data shall be held

Technical Requirements for BMS Programmable Controllers Read More »

Building Management System

Computer Based Central BMS Submittals & Controller Requirements

ACCEPTABLE BID PROCEDURES FOR BMS SYSTEM It is the intent of this specification to define a state-of-the-art distributed computerized software Integrated Building Management and Control System which is user friendly, has known reliability, is extremely responsive, and which is to be designed, installed, implemented, and supported by a local office of the manufacturer by people

Computer Based Central BMS Submittals & Controller Requirements Read More »

Building Management System