Agitator Installation Method Statement for Tanks and Vessels

The purpose of this Method statement is to explain the erection and installation of Agitator for tanks and vessels in Phosphoric acid plant or any chemical production facility. Function of the agitator is to maintain homogeneity in the fluid by creating turbulence. Generally Agitator consists of a big size shaft with a blade which is […]

Agitator Installation Method Statement for Tanks and Vessels Read More »

Civil Works Method Statements

Air Curtain Unit Preventive Maintenance & Troubleshooting

The purpose of this section is to provide guidance in preventive maintenance and basic fault tracing and provide instructions for corrective actions to remedy any faults. Go through this section, Fault tracing before contacting suppliers. To ensure the air curtain operates at full efficiency the inlet/outlet grilles, fan impellers, housings and motors must be kept

Air Curtain Unit Preventive Maintenance & Troubleshooting Read More »

HVAC Method Statements, Preventive Maintenance
blockset-lv-switchgear

Schneider Electric LV Switchgear Panels Features

Main Distribution Boards MDB – BLOCKSET The low voltage main distribution boards are Schneider Electric “BLOKSET” range of L.V Switchboards. Blokset switchboards are designed, manufactured and tested in accordance with IEC 60439-1 standards. BLOKSET, a modular multi – functional system has been designed to improve reliability and safety which: BLOKSET is a fully type tested

Schneider Electric LV Switchgear Panels Features Read More »

Technical Articles

Underground Drainage Piping Method Statement

This plumbing method statement covers the installation of Sanitary, Vent and Storm drainage piping installation. By following and implementing this procedure contractor shall ensure that drainage and vent piping have been installed as per the contract requirements and project specifications. Required Materials Tools and Equipment Schedule Personnel Protective equipment: All personnel should wear at all

Underground Drainage Piping Method Statement Read More »

Plumbing Method Statements

Refrigerant Gas Leakage Detection and Charging Method

The purpose of this AC repair method is to establish a standard procedure for identifying gas leaks on air conditioning and refrigeration system thus preventing release of refrigerant gas in the atmosphere. This method will also serve as guideline for new and old employees for performing the ac maintenance activity. The scope of this standard

Refrigerant Gas Leakage Detection and Charging Method Read More »

HVAC Method Statements, Preventive Maintenance
SMDB MDB FDB Specifications

SMDB, MDB, FDB LV Switchgear Panels & Distribution Board Construction & Specifications

The switchboards, distribution boards including smbd and control panels are built in accordance with IEC 439 “Factory Built Assemblies for Low Voltage” or BS 5486 “Factory-built Assemblies of Switchgear and Control Gear for Voltage up to and including 1000 AC and 1200V DC. Switchboards SMBD, MDB, FDB are always type tested conforming to tests conducted

SMDB, MDB, FDB LV Switchgear Panels & Distribution Board Construction & Specifications Read More »

Technical Articles
Steel Structure Building Construction Procedure

Steel Structure Building Construction Procedure

This procedure is useful for building construction based upon the project specifications for steel structure erection work. Based on the design and specification, this document provides a proper step wise procedure and quality and safety management of the steel structure works. The following items/equipments are basic requirements  for building construction of steel structure works at

Steel Structure Building Construction Procedure Read More »

Steel Structure & Fabrication