METHOD STATEMENT FOR TESTING AND COMMISSIONING OF CHILLERS

Below is detailed method statement for testing and commissioning of chiller. All the testing and commissioning work shall be done in accordance with mechanical specification and in accordance with the manufacturer’s instructions. Prior to starting the Chiller all electrical works related to supply of power to the equipment should be tested and energized. Furthermore, chemical… Read More »

Installation Method Statement for Cable Tray Ladder & Trunking

Below is the detailed cable tray installation method statement not only for cable tray but applicable for GI ladder and trunking for indoor and outdoor applications and in service rooms like pump rooms, electrical rooms and plant rooms etc. PREPARATION AND SUBMISSIONS BEFORE CABLE TRAY INSTALLATION All materials intended for cable tray, ladder and trunking shall… Read More »

Building Operation and Maintenance Manual Template In Word Format

Below is a complete template which can be used to prepare professional operation and maintenance manuals for building projects of any size and type. Details in each section depends upon the area of application. If project is of high value and more complex operations are involved much detail should be provided in relevant sections like… Read More »

Operating Instructions sprinkler system, landing valves, hydrant valve, hose reel valve, and extinguishers.

Operating Instructions for fire fighting system including sprinkler system, landing valves, hydrant valve, hose reel valve, and extinguishers. I. SPRINKLER SYSTEM Alarm Valve (i) Setting up of an Installation Control Valve assembly. State of Plant: Fire protection system mains pipework charged to system pressure up to the upstream side of Installation Control Valve. All Normally… Read More »

Maintenance Procedure For Fire Sprinkler, Stand Pipe, Hydrant & Hose Reel Systems

Maintenance Instructions for the maintenance of Fire Sprinkler, Stand Pipe, Hydrant & Hose Reel Systems including fire fighting pump sets. Maintenance Of Sprinkler System: Installation of Control Valve (Alarm Valve) It is recommended that the Alarm Valve be inspected periodically to ensure proper operation.  Several areas to be routinely inspected are: Clapper/Clapper Latch: The rubber clapper facing… Read More »

Download Method Statement For Compressed Air System Piping Installation

Download Method Statement For INSTALLATION & TESTING OF COMPRESSED AIR SYSTEM Now you can Download Method Statement, ITP, Installation & Pressure Test Checklists and Risk Assessment For Compressed Air System Piping Installation by paying a very nominal fees. The files are in word/excel format and instantly available after you pay the cost of only 2.99$. You… Read More »

Method Statement For Testing & Commissioning Of Fire Fighting Sprinkler System

Please arrange following instruments & tools for testing & commissioning of firefighting sprinkler system. Valve operating keys. Calibrated Pressure Gauges Heat gun Torque tester Flexible Hose Drums 300 liter to 500 liter Testing & Commissioning Sequence Pre-Commissioning Phase Before commissioning the system the following shall be ensured. The Installation and pressure testing of the pipes… Read More »

Method Statement For Testing & Commissioning Of Sump Pumps

This method statement covers the commissioning of Sump Pumps.  The objective is to check that the installation is correct and as per the manufacturer’s recommendations, to prove the pump volumetric performance and to test the alarm and interface signals to the BMS. Commissioning engineer will be responsible for the day to day activities on site,… Read More »